{"id":899,"date":"2019-04-11T01:09:31","date_gmt":"2019-04-11T01:09:31","guid":{"rendered":"http:\/\/www.imaginbot.com\/it\/?page_id=899"},"modified":"2019-04-11T01:49:14","modified_gmt":"2019-04-11T01:49:14","slug":"individuazione-guasti","status":"publish","type":"page","link":"https:\/\/www.imaginbot.com\/it\/individuazione-guasti\/","title":{"rendered":"Individuazione Guasti"},"content":{"rendered":"<div id=\"themify_builder_content-899\" data-postid=\"899\" class=\"themify_builder_content themify_builder_content-899 themify_builder\">\n\n    <\/div>\n\n\n\n<p style=\"text-align:left\"><strong><em>Problema: LED verde<\/em><\/strong><em>\npannello <strong>spento<\/strong> con interruttore generale attivato.<\/em><\/p>\n\n\n\n<p style=\"text-align:left\">Causa: Alimentatore 12 VDC\nnon funzionante, <strong>fusibile F4<\/strong>\ninterrotto. <\/p>\n\n\n\n<p style=\"text-align:left\"><strong><em>Problema: <\/em><\/strong><em>Uno\no pi\u00f9 <strong>driver<\/strong> non funzionano o presentano difetti.<\/em><\/p>\n\n\n\n<p style=\"text-align:left\">Causa: Collegamenti per\nogni singolo driver <strong>invertiti<\/strong> e\/o <strong>mancanti<\/strong>, impostazioni a <strong>dip-switch<\/strong> presenti sui singoli driver <strong>errate<\/strong>.<\/p>\n\n\n\n\n\n\n<p style=\"text-align:left\"><strong><em>Problema: Fusibile F1 <\/em><\/strong><em>interrotto<strong>.\n<\/strong><\/em><\/p>\n\n\n\n<p style=\"text-align:left\">Causa: <strong>Ventole esterne<\/strong> troppo potenti o <strong>guaste<\/strong>, <strong>ventola estrusore guasta<\/strong>, fili della ventola estrusore <strong>invertiti<\/strong> o <strong>contatti<\/strong> <strong>non voluti<\/strong>\nsugli stessi. <\/p>\n\n\n\n<p style=\"text-align:left\"><strong><em>Problema: Fusibile F2 <\/em><\/strong><em>interrotto<strong>.\n<\/strong><\/em><\/p>\n\n\n\n<p style=\"text-align:left\">Causa: <strong>Resistenza interna estrusore<\/strong> troppo <strong>fredda<\/strong> o in <strong>corto-circuito<\/strong>, <strong>ventola<\/strong>\nestrusore (comandata dal software) in <strong>corto-circuito<\/strong>,\n<strong>termistore<\/strong> su estrusore <strong>non collegato bene<\/strong>. <\/p>\n\n\n\n<p style=\"text-align:left\"><strong><em>Problema: Fusibile F3 <\/em><\/strong><em>interrotto<strong>.\n<\/strong><\/em><\/p>\n\n\n\n<p style=\"text-align:left\">Causa: Uno o pi\u00f9 <strong>alimentatori esterni difettosi<\/strong> e\/o <strong>guasti<\/strong>, <strong>troppa corrente<\/strong> richiesta dagli <strong>alimentatori esterni<\/strong> (in questo caso \u00e8 necessario parzializzare il\ncarico all\u2019accensione), <strong>varistore VR1\nguasto<\/strong> e\/o <strong>bruciato<\/strong> (visivamente\navvertibile). <\/p>\n\n\n\n<p style=\"text-align:left\"><strong><em>Problema: Fusibile F4 <\/em><\/strong><em>interrotto<strong>.\n<\/strong><\/em><\/p>\n\n\n\n<p style=\"text-align:left\">Causa: <strong>Alimentatori interni guasti<\/strong> e\/o <strong>difettosi<\/strong>, dispositivi di <strong>filtraggio guasti<\/strong> (osservare componenti\nnella zona prossima ad L3 se presentano visivamente imperfezioni). <\/p>\n\n\n        <link class=\"themify-builder-generated-css\" type=\"text\/css\" rel=\"stylesheet\" href=\"https:\/\/www.imaginbot.com\/it\/wp-content\/uploads\/themify-css\/themify-builder-919-generated.css?ver=1598057078\" \/>\n        <div class=\"themify_builder_content themify_builder_content-919 themify_builder not_editable_builder\" data-postid=\"919\">\n    \n\n\t\t<!-- module_row -->\n\t\t<div  class=\"themify_builder_row module_row clearfix module_row_0 themify_builder_919_row module_row_919-0\" data-id=\"fac597d\">\n\t\t\t\t\t\t<div class=\"row_inner col_align_top\" >\n                                    <div  class=\"module_column tb-column col-full first tb_919_column module_column_0 module_column_919-0-0\" data-id=\"c0dea89\" >\n                                                                <div class=\"tb-column-inner\">\n                            \n\n    <!-- module callout -->\n    <div  id=\"callout-919-0-0-0\" class=\"module module-callout callout-919-0-0-0 ui button-left green  rounded gradient repeat \" data-id=\"91ca615\">\n        <!--insert-->\n        \n        <div class=\"callout-inner\">\n            <div class=\"callout-content\">\n                <h3 class=\"callout-heading\">Scarica il Manuale Completo<\/h3>\n                <p>\n                Si, voglio scaricare subito il MANUALE COMPLETO in PDF                <\/p>\n            <\/div>\n            <!-- \/callout-content -->\n\n                            <div class=\"callout-button\">\n                        <a href=\"http:\/\/www.imaginbot.com\/it\/wp-content\/uploads\/imaginbot_com_v_a1_manuale.pdf\" class=\"ui builder_button red rounded\">\n                            Download PDF                        <\/a>\n                    <\/div>\n                        <\/div>\n        <!-- \/callout-content -->\n    <\/div>\n    <!-- \/module callout -->\n\n                        <\/div>\n                    \t\t<\/div>\n\t\t                                <\/div>\n                                <!-- \/row_inner -->\n                        <\/div>\n                        <!-- \/module_row -->\n\t\t\n<\/div>\n\n\n\n<p style=\"text-align:left\"><strong><em>Problema: Instabilit\u00e0 <\/em><\/strong><em>dei<strong>\nfine corsa. <\/strong><\/em><\/p>\n\n\n\n<p style=\"text-align:left\">Causa: <strong>Micro-switch<\/strong> <strong>collegati male<\/strong>, <strong>polarit\u00e0<\/strong>\ningressi micro-switch <strong>non osservata<\/strong>,\n<strong>DP2<\/strong> con predisposizioni <strong>errate<\/strong>. <\/p>\n\n\n\n<p style=\"text-align:left\"><strong><em>Problema: Riscaldamento\neccessivo <\/em><\/strong><em>o continuo del<strong> resistore interno\nestrusore. <\/strong><\/em><\/p>\n\n\n\n<p style=\"text-align:left\">Causa: <strong>Collegamenti<\/strong> termistore <strong>difettosi<\/strong>, <strong>errato<\/strong> <strong>collegamento<\/strong> del\ntermistore, il termistore ha un <strong>filo\nconnesso a massa<\/strong> e\/o terra anche se non previsto dal cablaggio. <\/p>\n\n\n\n<p style=\"text-align:left\"><strong><em>Problema: Instabilit\u00e0 <\/em><\/strong><em>nella<strong>\ncorsa dei motori passo-passo. <\/strong><\/em><\/p>\n\n\n\n<p style=\"text-align:left\">Causa: <strong>Cablaggi<\/strong> sui segnali che giungono ai\ndriver con <strong>fili troppo lunghi<\/strong> e\/o <strong>attorcigliati<\/strong>. <strong><\/strong><\/p>\n\n\n\n","protected":false},"excerpt":{"rendered":"<p>Problema: LED verde pannello spento con interruttore generale attivato. Causa: Alimentatore 12 VDC non funzionante, fusibile F4 interrotto. Problema: Uno o pi\u00f9 driver non funzionano o presentano difetti. Causa: Collegamenti per ogni singolo driver invertiti e\/o mancanti, impostazioni a dip-switch presenti sui singoli driver errate. Problema: Fusibile F1 interrotto. Causa: Ventole esterne troppo potenti o [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"builder_content":"","_links":{"self":[{"href":"https:\/\/www.imaginbot.com\/it\/wp-json\/wp\/v2\/pages\/899"}],"collection":[{"href":"https:\/\/www.imaginbot.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.imaginbot.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.imaginbot.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.imaginbot.com\/it\/wp-json\/wp\/v2\/comments?post=899"}],"version-history":[{"count":8,"href":"https:\/\/www.imaginbot.com\/it\/wp-json\/wp\/v2\/pages\/899\/revisions"}],"predecessor-version":[{"id":934,"href":"https:\/\/www.imaginbot.com\/it\/wp-json\/wp\/v2\/pages\/899\/revisions\/934"}],"wp:attachment":[{"href":"https:\/\/www.imaginbot.com\/it\/wp-json\/wp\/v2\/media?parent=899"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}